Asameters® E and N series are rugged flowmeters, suitable for measuring instantaneous flow of any type of fluid (gas and liquid), at temperature and pressure conditions kept within glass resistance limits, in absence of water hammer. They are ideal where it is essential to show the flow of medium through the glass measuring tube and the …
Variable Area Flowmeters
Glass Tube
Differential pressure regulators model R880 made of stainless steel 316L, when coupled with Asameters model 1900-1901-1903 in s.s. 316L, can keep flow rate constant in presence of variable inlet pressure (mod. 1911-13-15) or outlet pressure (mod. 1912-14-16). Chief performances are: a) maintaining a constant flow-rate independent of inlet pressure fluctuations b) maintaining a constant flow-rate independent of …
Metal Tube
Asameters model C-G…38/39 all made of stainless steel are designed for medium and high flow rates for every kind of gas (mod. C) and liquid (mod. G) also aggressive, at extreme operating and environmental conditions (high pressures and/or low or high temperatures). These Asameters are ideal for flow measurement where safety and product reliability are a must …
Asameters model C/G …47 _ 50 all made of stainless steel are designed for applications in potentially explosive areas thanks to their flameproof design, certified ATEX Ex ia IIC T4, T6… Zone 0 and Zone 1 (on request). They are suitable for medium and high flow rates with any type of gas (mod. C) or liquid …
Asameters model L…38 _ 39 all made of stainless steel are designed for low flow rates with any type of gas or liquid also aggressive, at extreme process and environmental conditions (high pressures and/or low or high temperatures). These Asameters are ideal for flow measurement where safety and product reliability are a must and not require power supply (in standard version …
Asameters model L …47 _ 50 all made of stainless steel, certified ATEX Ex ia IIC T4, T6 … Zone 0 and Zone 1 (on request), are designed for applications in potentially explosive areas thanks to their flameproof design. They allow you to meet the challenging needs of the application sites: hazardous areas, high temperatures, high pressures …
Orifice plate Asameters
Orifice plate Asameters, model O, are calibrated measuring devices suitable for liquid, gas and steam even in extreme operating conditions (high temperature, high pressure and corrosive liquids). They are manufactured and designed individually according to standard DIN EN ISO 5167 and ASME MFC-14M and provide excellent accuracy and a very wide range of flow rates through …
Panels for flow measurement, control and regulation
In the new ASA product catalog you find also integrated systems, commonly called panels, for the measurement, control and adjustment of flows, designed in agreement to customer specification for purge gas application, for flow regulation and flushing modules, for the control of pressure and flow. Our panels are manufactured with high quality materials and have …
Plastic Tube
Asameters® model P13 are designed for low and medium flows and made in anti-shock plastic material (Polisulfone or PVC depending on the requirement). They are suitable for use with aggressive fluids such as caustic soda, hydrocloridric acid or acids of another kind and in various concentrations. There are also reading scales in water and air or …
Electromagnetic Flowmeters
Sensors
Wafer sensor has a rugged and reliable build. All of its internal components and wiring are isolated from environmental hazards, even the toughest, because the measuring tube and the outer tube both in stainless steel are welded together to provide a hermetic seal. Therefore it’s maintenance free and provide a long-term reliability. Easy and fast to …
Signal Converters
This new model, at high performance solutions, both as hardware and software, can be defined as an HI-TEC line, addressed to very demanding customers from the point of view of performance and precision. Output signal is both analogical and digital; and qualitatively the instrument is very performing, having accuracy < +-0,5% of reading and repeatability …